ASHRAE 55-2004 PDF

Human Occupancy. ANSI/ASHRAE Standard Web site, http://www. , or in paper form from the Manager of Standards. The latest edition of . ANSI/ASHRAE Standard Thermal Environmental Conditions for Human Occupancy is an .. 5 December ^ Jump up to: ASHRAE Standard 55 ( ). ANSI/ASHRAE Standard 3. It is intended that all of the criteria in this standard be applied together since comfort in the indoor environment is.

Author: Mora Zolobar
Country: Sao Tome and Principe
Language: English (Spanish)
Genre: Travel
Published (Last): 7 June 2008
Pages: 223
PDF File Size: 8.90 Mb
ePub File Size: 20.87 Mb
ISBN: 973-4-15916-666-2
Downloads: 32687
Price: Free* [*Free Regsitration Required]
Uploader: Vojar

Retrieved from ” https: Generally, the evaluation of comfort in existing buildings can be performed from two perspectives: This method is based on the concept that when occupants choose their clothing according to their environment, the outdoor environment is more influential than the indoor one. When such measurement is not feasible, this standard provides four methods to determine the clothing insulation.

As for point-in-time surveys, the survey should be solicited during the time of occupancy, and the satisfaction scale ought to be continuous. For mechanically conditioned spaces, the PMV-based comfort zone has to be determined, which includes measuring and recording the metabolic awhrae and clothing insulation.

This is the energy produced from a unit skin surface area of an average person seated at rest. One has to keep in mind that the results from point-in-time surveys are only effective during the time when the surveys were solicited.

If these requirements are met and the environmental conditions inside the building fall within the indicated ranges, then compliance is achieved. It was revised in,and Except sedentary activities, metabolic rate for all other activities is likely ashrrae have range of variation.

For occupant-controlled naturally conditioned spaces, the measured results shall be check with the comfort zone established by adaptive model. For humidity ratios 552-004 0. The last major change concerns measuring air speed and air temperature experienced by the occupant, which now must be an average across three heights and over a period of time.

Interpretations for Standard 55-2004

For an occupant-controlled naturally conditioned asbrae, the exceedance hours are the sum of hours when the operative temperature falls outside of the lower and upper boundaries of the comfort zone. Clothing insulation refers to the heat transfer of the entire body, which includes the uncovered parts, such as hands and heads. A occupant-controlled naturally conditioned space is where the thermal conditions of the space are primarily regulated by occupant-controlled openings.

  ASTM E1049-85 PDF

The measured results should be evaluated against the adjusted comfort zone for the specific building. It is defined as per unit of skin surface area which equals to The section sets provisions for increasing the upper air temperature limit at elevated air speeds above 0.

In the first form, different zshrae wear different clothing due to factors that are not related to thermal conditions, and the second form is opposite.

To evaluate the thermal comfort over a period of time in a mechanically conditioned space, the exceedance hours are the sum of all the hours when the absolute value of PMV is greater than 0. This page was last edited on 12 Septemberat In the standard underwent significant changes with the addition of two thermal comfort models: The systems must be able to maintain these conditions within the expected range of indoor and outdoor operating conditions.

It was first published inand since has been updated every three to six years.

The measurement locations should be where the occupants are expected to spend time in. It also added a general satisfaction survey to section 7 intended to evaluate general thermal comfort in an occupied space, bringing the standard in line with current survey-based post-occupancy evaluation POE practices.

For satisfaction surveys, the thermal satisfaction scale shall end with choices: Comfort zone refers to the combinations of 55-2040 temperature, mean radiant temperature trand humidity that ahrae predicted to be an acceptable thermal environment at particular values of air speed, metabolic rate, and clothing insulation I cl [1].

So far, all the clothing insulation value can be used when the occupant is standing. By using this 55-20004, you agree to the Terms of Use and Privacy Policy.

In general, body motion decreases the clothing insulation by pumping air through clothing. For this model the standard provides a graph of acceptable indoor temperature limits at prevailing mean outdoor temperatures a mean of the daily mean outdoor temperatures of the previous 7—30 days. The most recent version of the standard was published in Section 7 underwent major revisions for measuring thermal comfort in existing spaces including procedures for physical measurements and survey methods, and how to evaluate and report results.

  ADENOMA PITUITARIO PDF

After the body of the standard there are 11 informative appendices. These values are valid for an average adult with surface skin area of 1. In the body of the standard was rewritten in mandatory language, with informative language moved from the body of the standard to informative appendices. Metabolic rate is the rate of transformation of chemical energy into heat and mechanical work by metabolic activities of an individual.

For a mechanically conditioned space at an instance in time, the PMV and SET model shall be used to establish the comfort zone, and the local thermal discomfort shall be evaluated against the limit posed this standard as well.

The answers of open-ended questions from “very dissatisfied” occupants should be documented for later analysis. The standard suggests that the time of measurements should last two or more hours long, and it should also be a representative time of the year for this specific building.

Interpretations for Standard

Views Read Edit View history. For the first, it is not correct to use the average clothing insulation value to determine the desired thermal conditions for all occupants. There should be at least seven points on the scale ending with “very acceptable” and “very unacceptable.

When extracting environmental data from the Building Administration System, one should evaluate the location, height, and time step of the 5-52004 based on the previous suggestion. Heating, ventilating, and ashraw conditioning Building engineering Heat transfer Architecture Architecture occupations.